Sizing (based on average waste water flow rate)

The products use rate can be easily adjusted based on the average wastewater flow rate. 


BACTIVATORŽ LS Series Model #

LS500

LS1500

Adjusted products use rate (ml/day)

125

250

500

1000

1500

Average flow rate (m3/d)1 up to

156

312

625

1250

1875

Average flow rate (MGD)1 up to

0.04

0.08

0.17

0.33

0.50

# Bacta-PurŽ XLG-KITs (14L) per year

3-1/4 6-1/2 13 26 39

# bag-in-box reservoirs connected for operation

1

1

1

2 (3)2

3

# weeks between reservoir replacement

16

8

4

4 (6)2

4

1 Dose rates can be increased in systems with high grease or waste concentrations or during initial cleaning; higher dose rates give faster results.

2 When three reservoirs are connected the number of weeks between reservoir replacements will be extended to 6.

 

 